This manual provides information for:
OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
PART NUMBER 141601 REV F (07/14)
MODEL HY-6G
HYPERSTEAM™
ATMOSPHERIC
CONVECTION STEAMER
· Self Contained
· Gas
· Capacity: 6 Steamer Pans (12” x 20” x 2-1/2”)
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
POST IN A PROMINENT LOCATION
Instructions to be followed in the event user smells
gas. This information shall be obtained by consulting
your local gas supplier. As a minimum, turn o the gas
and call your gas company and your authorized service
agent. Evacuate all personnel from the area.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unied Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to le
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - CONVECTION STEAMER

This manual provides information for:OPERATOR MANUALIMPORTANT INFORMATION, KEEP FOR OPERATORPART NUMBER 141601 REV F (07/14)MODEL HY-6G HYPERSTEAM™ AT

Page 2

10 OM-HY/6GInitial Start-UpAfter the HY-6G Steamer has been installed, test it to ensure that the unit is operating correctly.1. Remove all literatur

Page 3

OM-HY/6G 11OperationNOTE: Before the steamer can be operated as described in this section, the pilot burner flame must be established. For detail

Page 4 - Table of Contents

12 OM-HY/6GOperationB. Operating Procedure1. Press the ON switch/pad for the steamer. The steam generator will fill, and heat until the READY light

Page 5 - Current: 2.5 AMPs ± 10%

OM-HY/6G 13CleaningWARNINGDISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE STEAMER.KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTRO

Page 6 - Water Quality & Treatment

14 OM-HY/6GCleaningDELIMING STEPS HY-6G (Use Touch Pad):STEP 1Press ON/OFF to turn steamer off. Open door.STEP 2Let cavity cool for 5 minutes or longe

Page 7 - Inspection & Unpacking

OM-HY/6G 15MaintenanceThe HY-6G Steamer is designed for minimum maintenance, and no user adjustments should be necessary. Certain parts may need

Page 8 - Installation

16 OM-HY/6GTroubleshootingThis Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list o

Page 9

OM-HY/6G 17Parts ListExternal Cabinet & Sheet MetalTo order parts, contact your authorized Groen Service Agency. Supply the model designatio

Page 10 - Initial Start-Up

18 OM-HY/6GParts ListCavity Control SectionKey Description Part #x Top Cover Clip 1231562 Timer 096826x Door Switch 0968574 Ready Thermostat 0888655 S

Page 11 - Operation

OM-HY/6G 19Key Description Part #x Adjustable Table Leg 0425052 Gas Switch 0879513 Main Gas Valve:Natural GasPropane Gas098443098444x Alternate

Page 12

2 OM-HY/6GIMPORTANT - READ FIRST - IMPORTANTWARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROP

Page 13 - Cleaning

20 OM-HY/6GParts ListSteam Motor & ControlsKey Description Part #1 Fan Motor w/Mounting Plate 0967402 Motor Shaft Seal 0968683 Motor Insulator 094

Page 14

OM-HY/6G 21Parts ListSteam Generator Individual PartsKey Description Part #1 Steam Generator Weldment 141619x* Right Steam Generator Insul. 0968

Page 15 - Maintenance

22 OM-HY/6GParts ListSteamer - Individual PartsKey Description Part #1 MAin Gas Valve 0999882a Gas Manifold, Left 1413412b Gas Manifold, Right 1413413

Page 16 - Troubleshooting

OM-HY/6G 23Electrical Schematic

Page 17 - Parts List

24 OM-HY/6GService LogModel No: Purchased From:Serial No: Location:Date Purchased: Date Installed:Purchase Order No: For Service Call:Date Maintenance

Page 21

PART NUMBER 141601 REV F (07/14)1055 Mendell Davis Drive • Jackson MS 39272888-994-7636 • 601-372-3903 • Fax 888-864-7636unifiedbrands.net© 2014 Unifie

Page 22 - Steamer - Individual Parts

OM-HY/6G 3WARNING: DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANELS HAVE BEEN RETURNED TO THEIR PROPER LOCATIONS.NOTICE: DO NO

Page 23 - Electrical Schematic

4 OM-HY/6GImportant Operator Warnings ...page 2-3References...

Page 24 - Service Log

OM-HY/6G 5Your Groen HY-6G HyPerSteam Convection Steamer is designed to give years of service. It has two stainless steel cavities (cooking cham

Page 25 - OM-HY/6G 25

6 OM-HY/6GWater Quality & TreatmentIt is essential to supply the steam generator with water that will not form scale or cause corrosion. Even tho

Page 26 - 26 OM-HY/6G

OM-HY/6G 7Inspection & UnpackingCAUTIONSHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.Your HY-6G HyPerSteam will be delivered

Page 27 - OM-HY/6G 27

8 OM-HY/6GThe HY-6G steamer is suitable for installation on or near both combustible and noncombustible surfaces. Minimum installation clearances are:

Page 28

OM-HY/6G 9Installation For a unit on casters, complete connection to the gas supply with connectors that comply with the standard for connector